W130 Rugged Laptop Computer
|
|
| Temperature |
|
- IEC 68-2-1,2,14 / MIL-STD-810F, Method 501.4,
502.4 Operating: 0°C to 55°C/32°F to 131°F
- Optional: -20°C to 55°C/-2°F to 131°F
Non-operating : -40°C to 70°C/-38°F to 158°F
|
| Humidity |
|
- According to IEC 68-2-30 / MIL-STD-810F,
Method 507.4
5% to 95% RH, non-condensing
|
| Altitude |
|
- According to IEC 68-2-13 / MIL-STD-810F,
Method 500.4
Operating: 15,000ft
Non-operating: 40,000ft
Altitude change rate: 2,000 ft/min
|
| Shock |
|
- According to IEC 68-2-27 / MIL-STD-810F,
Method 516.5
Operating: 15g/0.53 oz, 11 ms, half sine wave
Non-operating: 50g/1.76 oz, 11 ms, half sine wave
|
| Vibration |
|
- According to IEC 68-2-6 / MIL-STD-810F,
Method 514.5
Operating: 10~55Hz/0.075g, 55~500Hz/1.0g
Non-operating: 10~55Hz/0.15g, 55~500Hz/2.0g
- Highway truck vibration exposure
|
| Drop |
|
- According to IEC 68-2-32 / MIL-STD-810F,
Method 516.5
3 Feet height free drop still survive, (test surface: concrete, base
unit only)
|
| Enclosure |
|
- According to MIL-STD-810F/IEC 529, NEMA
- Regulation FCC part 15, Subpart B, Class B, UL,
CUL, TUV, CE, CCC, WHQL, BSMI,
- MIL-STD-461E(option): CE102; CS114, 115 & 116;
RE102; RS103
- IP rating: A770-IP54; W130-IP51; CA25T/CA27-IP52
|
|
|